Technical Support Social & Behavioural Sciences (TOP)

Psychofysiologische labs

During the use of the labs researchers must follow the guide-lines Guidelines for Hygienic Working’.

L1.04/1.05 - Eye tracking and VSRRP lab

Eye tracker: FaceLAB 5.0
Data acquisition: Vsrrp98, 2 x EMG, ECG, SCL
Stimulus presentation: Presentation, E-Prime 2, Inquisit 3
120Hz stimulus monitor

L1.23/1.24 - VSRRP lab

Data acquisition: Vsrrp98, UvA EMG/ECG/SCL
Stimulus presentation: Presentation, E-Prime 2
60Hz stimulus monitor (22”, 1680x1050, Asus type VW222U)
Additional equipment:
FMS Finometer MIDI continuous blood pressure monitor

  • Tel: 0205256393

L1.26/1.27 - VSRRP lab

Data acquisition: Vsrrp98, UvA EMG/ECG/SCL
Stimulus presentation: Presentation, E-Prime 2
60Hz stimulus monitor (22”, 1680x1050, Asus type VW222U)
Additional equipment:
Digitimer DS-7A constant current stimulator
2 channel respiration belt amplifier
blush meter (plethysmograph)
blush meter (skin temperature)

  • Tel: 0205256710

L1.28/1.29 - VSRRP lab

Data acquisition: Vsrrp98, UvA EMG/ECG/SCL
Stimulus presentation: Presentation, E-Prime 2
60Hz stimulus monitor (22”, 1680x1050, Asus type VW222U)
Additional equipment:
Digitimer DS-7A constant current stimulator

  • Tel: 0205256705

L1.30/1.31 - VSRRP lab

Data acquisition: Vsrrp98, UvA EMG/ECG/SCL
Stimulus presentation: Presentation, E-Prime 2
60Hz stimulus monitor (22”, 1680x1050, Asus type VW222U)
Additional equipment:
Digitimer DS-7A constant current stimulator
Ohmeda Finapres 2300 continuous blood pressure monitor

  • Tel: 0205256706

DL1.37/1.38 - VSRRP lab

Data acquisition: Vsrrp98, UvA EMG/ECG/SCL
Stimulus presentation: Presentation, E-Prime 2
60Hz stimulus monitor (22”, 1680x1050, Asus type VW222U)
Additional equipment:
Digitimer DS-7A constant current stimulator
Software controllable colour LED lamps
FMS Finometer MIDI continuous blood pressure monitor

  • Tel: 0205256707

L1.39/1.40 - VSRRP lab

Data acquisition: Vsrrp98, UvA EMG/ECG/SCL
Stimulus presentation: Presentation, E-Prime 2
60Hz stimulus monitor (22”, 1680x1050, Asus type VW222U)
Additional equipment:
Digitimer DS-7A constant current stimulator
Software controllable colour LED lamps

  • Tel: 0205256708

 L1.25 - cleaning room

 L1.25 is the room where you can clean and disinfect your electrodes and electrode caps. Use the ultrasonic cleaning unit to remove dirt (for example old electrode paste) from the electrode caps after measuring few subjects.